A Study to Assess The Quality of Spinal Anesthesia and to Observe Hemodynamic Changes Occuring During Cesarean Section with Spinal Anesthesia, Comparing 0.5% Isobaric Bupivacaine and 0.75% Hyperbaric Bupivacaine in Same Volume And Dose.

Authors: Abdul Sattar Narejo, Ghulam Nabi Memon, Farida Wagan, Mehboob Ahmad Wagan, Ali Khawaja

1 KING KHALID UNIVERSITY HOSPITAL OF KING SAUD UNIVERSITY, RIYADH, KSA.
2 PEOPLES UNIVERSITY OF MEDICAL AND HEALTH SCIENCES FOR WOMEN, SHAHEED BENAZIRABAD, DISTRICT NAWABSHAH, SIND PAKISTAN.
3 KING ABDUL AZIZ UNIVERSITY HOSPITAL OF KING SAUD UNIVERSITY, RIYADH, KSA.
4 PEOPLES UNIVERSITY OF MEDICAL AND HEALTH SCIENCES FOR WOMEN, SHAHEED BENAZIRABAD, DISTRICT NAWABSHAH, SINDH, PAKISTAN
5 DEPARTMENT OF PHARMACOLOGY. LIAQUAT UNIVERSITY OF MEDICAL &
HEALTH SCIENCES, JAMSHORO, SIND, PAKISTAN
6 KING KHALID UNIVERSITY HOSPITAL, KING SAUD UNIVERSITY RIYADH, KINGDOM OF SAUDI ARABIA.

Volume 18 | Issue 1

Published: November 6, 2026

Abstract

of this study is to assess the quality of spinal anesthesia block and observe hemodynamic changes occurring during c-section, comparing two different baricities of bupivacaine i.e. 0.5% isobaric and 0.75% hyperbaric in same doe and volume. Design: Quasi experimental study. Place and Duration of Study: Department of Anesthesiology and ICU, Shalamar Hospital, Lahore, from April 2007 to October 2007. Patients and Methods: Sixty, adult patients of ASA I and II, undergoing elective lower segment cesarean section were included in this study. The patients were randomly divided into two groups, Group-I received isobaric 0.5% bupivacaine 2.5 ml (12.5 mg) and groupII received Hyperbaric 0.75% bupivacaine 2 ml in which 1 ml of CSF was added and then 2.5 ml injected (12.5 mg), so that both groups receive equal volume and dose of bupivacaine but different baricities. Quality of block was assessed by pin prick and Bromage Scale for sensory and motor block respectively. Hemodynamic changes were compared with the base line readings. . Results: No significant difference was found between the two groups regarding the quality of block but there were significant hemodynamic differences, in group-I, initial maximum increase in heart rate and decreases in MAP were observed at 2 minutes. While in group-II, maximum increase in heart rate was observed immediately after injection and maximum decrease in MAP was at 2 minutes. This shows that there was immediatedecrease in MAP, which may be due to faster onset of sensory block in group-II, when compared with group-I.
Conclusion: No significant differences were found between the two groups regarding the quality of block. But the rapid onset of sensory block with 0.75% hyperbaric bupivacaine in group 11 produced more hypotension, when compared with 0.5% isobaric bupivacaine in group 1 but it was not statistically significant.

Keywords: Spinal anaesthesia, Bupivacaine, isobaric, hyperbaric, block quality, hemodynamic change in c- section after spinal.

DOI: (All papers should be submitted electronically. All submitted manuscripts must be original work that is not under submission at another journal or under consideration for publication in another form, such as a monograph or chapter of a book. Authors of submitted papers are obligated not to submit their paper for publication elsewhere until an editorial decision is rendered on their submission. Further, authors of accepted papers are prohibited from publishing the results in other publications that appear before the paper is published in the Journal unless they receive approval for doing so from the Editor-In-Chief.)

Download Full Text PDF