Authors: Shahzad Ahmad1, Sajjad Khan, Muhammad Zaheer Ullah Babar, Waheed Iqbal
Abstract
Objective: This study aimed to assess the diagnostic accuracy of the Tourniquet test in comparison to dengue IgG/IgM tests among patients with dengue fever. Study design: A cross-sectional validation study was conducted. Place and Duration of Study: The study was carried out at Northwest General Hospital and Research Center from January 2017 to December 2018. Material and Method: A total of 150 confirmed cases of dengue fever were included using non-probability convenience sampling. Patients with chronic liver disease, chronic renal failure, or those on anticoagulant/antiplatelet therapy were excluded. The diagnostic accuracy of the Tourniquet test was evaluated within the first 24 hours of admission. Comparison was made between dengue antibodies and the Tourniquet test. Results: Comparison of diagnostic accuracy between the Tourniquet test and dengue IgM/IgG, considered as the gold standard, revealed 16% true positives, 8.6% false positives, 38% true negatives, and 37.3% false negatives. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were calculated as 30%, 81.42%, 64.86%, 50.44%, and 59.6%, respectively. There was no statistically significant difference between the dengue IgM/IgG gold standard and the Tourniquet test for diagnosing dengue fever (p-value = 0.1, 95% CI 0.9682-1.769). Conclusion This study suggests that the Tourniquet test exhibits lower sensitivity but higher specificity and moderate diagnostic accuracy, indicating its potential utility in diagnosing acute dengue fever, particularly in resource-limited endemic areas.
Keywords: Dengue fever, Diagnosis, Tourniquet test.