Implementation Of Material Filter Technique For Scatter Correction In TC-99M Planar Imaging Of Thyroid: Phantom Study

Authors: Inayatullah Shah Sayed, Ahmad Zakaria, Nazifah Abdullah, Norhanna Sohaimi, Mohammad Shahrir Abdul Rahim, Soo Foon Moey, Farah Wahida Ahmad Zaiki

1 Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, 25200 Kuantan, Pahang, Malaysia,
2 School of Health Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kota Bharu, Kelantan, Malaysia,
3 Faculty of Health Science, Universiti Sultan Zainal Abidin (UniSZA), Gong Badak Campus, 21300 Kuala Terengganu, Terengganu, Malaysia,
4 Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, 25200 Kuantan, Pahang, Malaysia, 5 Breast Centre, Jalan Hospital, Kulliyyah of Medicine, International Islamic University Malaysia, 25200 Kuantan, Pahang, Malaysia,
6 Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, 25200 Kuantan, Pahang, Malaysia,
7 Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, 25200 Kuantan, Pahang, Malaysia,

Volume 24 | Issue 1

Published: October 29, 2026

Abstract

Inclusion of scattered gamma photons in nuclear medicine image data degrade the image quality. Number of scatter correction techniques is available unfortunately none of the method is applied in clinical studies. Thus, the objective of this study was to implement the material filter technique to enhance the quality of images in Tc-99m planar imaging of thyroid by removing scattered gamma photons prior to their detection. Methods: Picker thyroid phantom was scanned with Philip ADAC Forte gamma camera mounting low energy high resolution collimator. A flat sheet of zinc material (55 x 44 cm2) of 0.2 mm thickness was placed over the outer surface of the collimator. Tc-99m radionuclide (10mCi) was injected into the phantom. Planar images of the phantom with and without material filter were acquired. Four hundred thousand counts in each image were collected by selecting a 256 x 256 sized matrix. ImageJ software was used to analyze the acquired images. Results: Enhancement in image quality of cold and hot regions was attained with the usage of material filter. Significant (p <0.05) reduction in percent root mean square noise (PRMSN) was indicated in the background count density of cold and hot regions with material filter. Conclusion: The use of zinc material as a filter could play a significant role in Tc-99m thyroid scintigraphy as high perceived image quality enable qualitative and quantitative information of the organ of interest, lesion features, analysis of shapes and textures to be extracted efficiently and accurately in achieving higher diagnostic accuracy.

Keywords: Material filter, scatter correction, image quality, thyroid nodules

DOI: (All papers should be submitted electronically. All submitted manuscripts must be original work that is not under submission at another journal or under consideration for publication in another form, such as a monograph or chapter of a book. Authors of submitted papers are obligated not to submit their paper for publication elsewhere until an editorial decision is rendered on their submission. Further, authors of accepted papers are prohibited from publishing the results in other publications that appear before the paper is published in the Journal unless they receive approval for doing so from the EditorIn-Chief.)

Download Full Text PDF